Conformity AssessmentLast updated 2026-11-22

Which bodies can certify products under the Cyber Resilience Act?

None yet. On 22 November 2026, no conformity assessment body was listed in NANDO, the European Commission database, under the Cyber Resilience Act, Regulation (EU) 2024/2847. Five Dutch certification bodies hold temporary CRA accreditations from the Dutch Accreditation Council (RvA). An accreditation is a step before notification and does not let a body issue CRA certificates as a notified body.

Key takeaways

  • The Dutch Accreditation Council (RvA) gave the first Cyber Resilience Act accreditations to BSI, UL International, DEKRA, Brightsight and TrustCB, and announced them on 3 November 2026.
  • The RvA register holds nine CRA accreditations for these five bodies, granted between 12 August and 28 October 2026.
  • All five bodies hold Module B (EU-type examination). Four hold Module H (full quality assurance). TrustCB holds Module B only.
  • Each CRA accreditation is temporary, has restrictive conditions and is valid for one year.
  • A body becomes a CRA notified body only after the Dutch notifying authority (RDI) notifies it and the body appears in NANDO.

What the RvA accredited

On 3 November 2026, the RvA announced the first certification bodies accredited for Regulation (EU) 2024/2847. The announcement names BSI, UL International, DEKRA, Brightsight and TrustCB. The RvA states that it is the first accreditation body in Europe to grant accreditations for this regulation.

The RvA scope documents, read on 22 November 2026, record nine accreditations for five Dutch legal entities.

Legal entityModule B (Annex VIII Part II, EN ISO/IEC 17065:2012)Module H (Annex VIII Part IV, EN ISO/IEC 17021-1:2015)
UL International (Netherlands) B.V.C648, granted 12 August 2026C721, granted 24 September 2026
DEKRA Certification B.V.C001, granted 26 August 2026C013, granted 26 August 2026
SGS Brightsight B.V.C702, granted 26 August 2026C717, granted 22 October 2026
TrustCB B.V.C651, granted 26 August 2026None
BSI Group The Netherlands B.V.C646, granted 28 October 2026C122, granted 28 October 2026

Each scope covers critical, important class I, important class II and default-category products. There is one exception. The Brightsight Module H scope (C717) does not cover default-category products.

Each CRA scope uses the same words. It is "a temporary accreditation with restrictive conditions" and is "suitable for notification". It is valid for one year from the grant date.

Why is accreditation not notification?

Two different authorities do the two steps. The RvA is the Dutch national accreditation body. The Rijksinspectie Digitale Infrastructuur (RDI) is the Dutch notifying authority. A body becomes a notified body after its Member State notifies it to the European Commission. The body then appears in NANDO.

A check of NANDO on 22 November 2026 found no body listed under Regulation (EU) 2024/2847.

The BSI press release shows the same gap. BSI calls its status "pre-accreditation". It lists three steps that are still open. The steps are notification through the RDI, a pilot conformity assessment and final designation. The press release gives no dates for these steps.

Which module does each body cover?

The module and the product class must both be in the scope of the body. CRA Annex VIII defines the two modules.

  • Module B (EU-type examination, Annex VIII Part II) examines the design and the product type. It ends in an EU-type examination certificate. All five bodies hold a temporary Module B scope.
  • Module H (full quality assurance, Annex VIII Part IV) approves the quality system of the manufacturer. The quality system covers design, development, production and testing of products, and vulnerability handling. Four of the five bodies hold a temporary Module H scope. TrustCB holds Module B only.

An accreditation under the Radio Equipment Directive or EUCC gives a body no automatic status under the CRA. On 16 November 2026, ENISA published "CRA-Module B and H: CABs accreditation for notification" (version 2.6). The report compares these accreditations with the requirements for CRA Module B and Module H.

Which products need a notified body?

CRA Article 32 sets the conformity route for each product class. An important class I product needs a notified body when the manufacturer does not apply in full a harmonised standard, a common specification or a European cybersecurity certification scheme. An important class II product needs a notified body or a European cybersecurity certification scheme. A critical product can need a European cybersecurity certification scheme under Article 32(4). When no scheme applies, a critical product uses the class II routes. There is one exception for important products. Under Article 32(5), a class I or class II product that is free and open-source software can use the default-category procedures, including Module A, when the manufacturer makes the technical documentation public.

What happens next?

The notified body rules in CRA Chapter IV apply from 11 June 2026, under Article 71(2). The main obligations apply from 11 December 2027. The first accreditation was granted on 12 August 2026, about 16 months before that date. RDI notifications, pilot assessments and NANDO listings are still open.

A manufacturer with a product under Article 32 can use this time to choose between Module B and Module H. The manufacturer can also check that a body holds the correct module and product class. Treat a body as a CRA notified body only after it appears in NANDO.

The CVD Portal notified body directory shows the accreditation status of each body on its review date.

Sources. The RvA announcement of 3 November 2026, the RvA scope documents linked in the table above (read 22 November 2026), the BSI press release, the European Commission NANDO list for Regulation (EU) 2024/2847 (checked 22 November 2026), ENISA, CRA-Module B and H: CABs accreditation for notification (version 2.6, 16 November 2026), and Regulation (EU) 2024/2847 on EUR-Lex (CELEX 32024R2847, ELI http://data.europa.eu/eli/reg/2024/2847/oj), Article 32, Chapter IV, Article 71(2) and Annex VIII.